High Pressure Transmitter line LPH1022A up to +85°C, current output
Configuration
Features of LPH line
Compact design, extreme robust by welded housings and dry titanium sensor cells made from only one material on media side.
Range: 1000 bar up to 5000 bar
Operating temperature: -40°C / +85°C
Sensivity error: < 0,3%span
Current output: (4 … 20) mA
Non ratiometric
Supply voltage: (8 ... 40) VDC
Vibration proofness: >20 g
Electrical interfaces: M12x1; DIN EN 175301-803; Cable