High Pressure Transmitter line LPH1022A up to +85°C, current output


Configuration

Your data

Your request


Features of LPH line

Compact design, extreme robust by welded housings and dry titanium sensor cells made from only one material on media side.

Range: 1000 bar up to 5000 bar
Operating temperature: -40°C / +85°C
Sensivity error: < 0,3%span
Current output
: (4 … 20) mA

Non ratiometric

Supply voltage: (8 ... 40) VDC

Vibration proofness: >20 g
Electrical interfaces
: M12x1; DIN EN 175301-803; Cable

 

Detailed configuration

Series specification as PDF

Further technical details of this transmitter series you will find in our product specification for the LPH10 line.

Download now